Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 7.5.7 Summary on compensating windings . (a) The preferable arrangement is to have compensating windings in an even number of slots per pole face. A single series compensating winding that carries full armature current can be used in this case . (b) If an odd number of slots must be used. this can be done provided the number of poles is an integral multiple of four. Two parallel windings are used in this case, each carrying half armature current. (c) The combination of an odd number of slots per pole face and a number of poles that is not an integral multiple of four should not be used in minesweeping generators.
(d) End connections should be so arranged that the current loops in the planes of the end connectors at the two ends of the machine sum up to zero net magnetic moment at each end. 8. ARRANGEMENT OF STORAGE BATTERIES FOR LOW STRAY MAGNETIC FIELDS 8.1 Battery arrangements. In this section we consider the arrangement of storage batteries and the design considerations that will reduce the stray magnetic field produced by the current through che batteries and their associated connections. 8.1.1 Batteries on minesweepers. The design consideration for batteries on minesweepers will be as specified in 8.1.1.1 through 8.1.1.6. 8.1.1.1 Use of storage batteries.
We use storage batteries on minesweepers to supply power for a number of purposes, such as starting small engines. It would be preferable to have all engines on minesweepers started nonelectrically because this would eliminate all stray magnetic field problems caused by electric starting. Pending the trial and approval of suitable nonelectrical starting methods, however, electric starting will be used for at least some of the engines on minesweepers. Even when electric starting of engines on minesweepers is eliminated, we will still use storage batteries for other purposes. 8.1.1.2 Types of battery trays.
The three-cell, 6-volt battery tray arrangements covered by this section will be of the following types: (a) Type I - When you look down on the top of the tray, with the cells oriented in the vertical direction, and the top cell terminals negative-positive from left to right, make the external negative battery connection at the top of the tray and the external positive battery connection at the bottom of the tray (see figure 107).
(b) Type II- When you look down on the top of the tray, with the cells oriented in the vertical direction, and the top cell terminals negative-positive from left to right, make the external positive battery connection at the top of the tray and the external negative battery connection at the bottom of the tray 107). 177