Downloaded from https://www.everyspec.com MIL-HPBK-802(SH) 2 July 1990 where: PO = I = > = > > i , j = permeability of free space. current. denotes a vector quantity, unit vectors in x and y directions, respectively. 3.4.1.3 Loops. Next we will see the effect on the stray magnetic field when we bend the wire into the two distinctive (but basic) loops. Again, the difference between the expressions is based upon the effect of two different geometric shapes, a rectangular (see 3.4.1.3.1) or a circular (see 3.4 1.3.2) loop of wire. FIGURE 10. Finite straight wire along the z axis. 3.4.1.3.1 Square loop.
Assume a square loop lies in the xy plan with each side of length L (see figure 11) (note that the case of a rectangular loop is addressed in 4.2.2). The magnetic field at the center of the square loop is equal to four times that caused by a single side. If we use the finite straight wire equation and set r = L/2, we obtain the following square loop equation for the magnitude of the magnetic field (B): 10