Downloaded from https://www.everyspec.com where: Po = permeability of free space. I = current. L = length of wire segment per side of loop. The direction of B and that of the current in the loop will follow the right hand rule (see 3.4.1.1.1). For the example giver. above with th e current in the clockwise direction, the magnetic field will be in the positive z direction The example given above is for the simple case of a square loop with the field measured at the center of the loop, Rectangular loop equations for the field measured at any point in space are given in 4.2,2. FIGURE 11. Rectangular current loop in the xy plane. 3.4.1.3.2 Circular loop.
Assume the loop lies in the xy plane with its center at the origin (see figure 12). The magnetic field (B) measured at the origin for a loop of radius a, which as in the rectangular case represents the maximum value, is: and, the magnetic field at any point along the z axis is: where: P = permeability of free space. I = current. a = radius of the loop. z = length along the z axis. 11