Downloaded from https://www.everyspec.com (b) Now use the large loop formula (see equation 4-35) to compute the magnetic field at different points on a line parallel to and 0.5 meter below the x axis. The values computed by the large loop formula are shown in curve A of figure 13. They are equal (within the acceptable errors of measurement) to the values which would be measured by a magnetometer Now use the small loop (or dipole) formula (see equation 4-29) to compute the magnetic field at different points on the same line parallel to the x axis and 0.5 meter below it. The results computed by the small loop formula are shown in curve B of figure 13.
It is immediately apparent in this case that the small loop (or dipole) formula gives a very poor approximation relative to the correct values shown in curve A. Now use both the large and small loop formulas to compute the vertical component of the magnetic field on a line parallel to the x axis but 10.0 meters below it. The values computed by the large and small loop formulas agree to within a few percent. (c) (d) FIGURE 13 Comparison of large loop (A) and small loop (B) formulas. 4.1.2.2 Comparison of small and large loop formulas.
As the above example illustrates, at 10.0 meters below a loop 2.0 meters long and 1.0 meter wide, the small loop formula gives a good approximation to the correct value: at 0.5 meter below the loop, it gives a very poor approximation. There is no sharp dividing line between small and large loops: however, the following example may be used as