NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802 (SH) 2 July 1990 a guide. Suppose it is desired to calculate the magnetic field produced by a current loop at points on a plane z meters below the center of the loop, then the following would apply. (a) If the greatest distance between any two points on the loop is less than z/10, the small loop formulas will give results correct to a degree of approximation which is usually adequate fcr stray field calculations . The smaller the loop, as compared to z, the better the approximation.

(b) If the greatest distance between any two points on the loop is more than z/10, the approximation will not be as good, becoming worse as the loop becomes larger. Note, however, that the example given above shows a good approximation even when the greatest distance between any two points on the loop is slightly more than z/5. 4.1.2.3 Small loop formulas. The small loop formulas are much easier to use than the large loop formulas and will give results as needed This is because, in almost all cases, the greatest distance between any two points on the loop is less than z/10 (usually considerably less).

The formulas for large rectangular loops, given in 4.2.2, are included for the sake of completeness so as to be available in the rather unusual case of having to calculate the magnetic field close to a rectangular loop. 4.1.3 coordinate Coordinate axes. Throughout this handbook, a rectangular (Cartesian) system is used. The coordinate axes are as shown on figure 14 4.1.4 Conventions on sign. (a) A component of magnetic moment or of magnetic field along a particular coordinate axis is positive when in the same direction as the positive direction of the axis.

(b) A magnetic moment with its axis on a line passing through the origin 01 coordinates is positive if the positive direction of the moment is away from the origin. 17