NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-8O2(SH) 2 July 1990 5.5.2 Limitation of the principle. Let us consider the piece of equipment of 5.5.1. Divide the 1.5 meter cube into 1000 small cubes, each 15 centimeters on a side. Now suppose that the net magnetic moment for the current loop in each of the small cubes is zero. The principle of zero magnetic moment is therefore satisfied for the whole piece of equipment and for each of the small cubes. Furthermore because of the small size of the cubes, it is to be expected that the magnetic moments of the individual current loops each contains will be small, and it is certain that they will be quite close together.

Despite this, it is not certain that the stray magnetic field generated by this piece of equipment will be small. For instance, if we suppose that in each of the small cubes the current loops are exactly alike and are oriented in the same way, the stray magnetic field generated by the equipment would then be approximately 1000 times as large as the stray magnetic field generated by one of the small cubes. While the stray magnetic field of one of the small cubes may indeed be negligible, the magnitude of the stray magnetic field generated by the entire equipment could be too large to be tolerated. Although the preceding example is a rather unlikely situation, it is possible.

Application of the principles of minimum magnetic moment, minimum separation, and zero net magnetic moment does not guarantee that the stray magnetic field generated by the equipment will be small. It is, therefore, necessary to make a final check to be completely certain, 5.6 Principles of series and parallel compensation. Series compensation is illustrated on figure 44 (A), parallel compensation on figure 44 (B). 5.6.1 Comparison of series and Parallel compensation. Suppose that on figure 44 (A) and figure 44 (B) the current loops are coplanar, have the same size, shape and number of turns, and carry the same current.

When these conditions are satisfied, the two loops will generate exactly the same stray magnetic field, and there is no difference between series and parallel compensation, Nonetheless, series compensation is preferred because of the greater likelihood that the conditions for compensation will be satisfied (see 5.6.1.1). 5 6.1.1 Inequality of current division 5.6.1.1.1 Series compens ation. There is no problem with unequal current division in series compensation. Let us consider two opposing loops connected for series compensation. The current will, at all times, be the same in both loops; if the current changes in one loop it must change in the other.

There is the possibility that insulation will deteriorate so that the current can leak out of the circuit and cause the currents in the two loops to differ. However, if even a few amperes leak out of the loop the insulation will deteriorate so rapidly and will be so badly damaged that the circuit cannot be used. When two loops are connected in series, we can be sure either that the current is the same in both loops or that, if it differs by a significant amount, insulation failure will take the circuit out of use, 75