NAVSEA MIL-HDBK-802(SH) — MIL-HDBK-802(SH) Design of Electrical Equipment with Small Stray Magnetic Fields Manual PDF

Downloaded from https://www.everyspec.com MIL-HDBK-802(SH) 2 July 1990 5.6.1.1.2 Parallel compensation. Conditions are different with two loops connected for parallel compensation. Suppose that the two loops are of equal area, number of turns, and resistance. They will divide the total current equally and compensation should be satisfactory. The difficulty with parallel compensation is that so many things can happen to disturb this satisfactory situation. One loop may heat up more than the other, its resistance will become higher, and the current in it will be less than the other loop.

Contact resistance may change over the course of time, and, since the total resistance of each loop will be low, a change in contact resistance may be enough to create an appreciable inequality of current division. In the extreme case, one loop could develop an open circuit, force the other to carry the total current, and completely destroy compensation. Furthermore, this condition might exist for a considerable period of time before it becomes apparent. In view of this, it is apparent that series compensation is preferred to parallel compensation whenever series compensation can be employed.

When parallel compensation is used, either because series compensation is impractical, or because parallel compensation has other advantages which justify its use, the precautions given in 5.7 should be observed. 5.7 Use of parallel compensation. There are a number of cases where parallel compensation must be used. A minesweeping generator has a number of parallel circuits that are inherent in the construction of the machine. Parallel compensation is also needed for minesweeping cable runs. In other cases it has advantages that justify its use even when series compensation might be possible.

It should be kept in mind that while parallel compensation has drawbacks when compared to series compensation, it has advantages as well and can be used effectively if the precautions given below are observed. 5.7.1 Symmetry Take two circuits that are connected in parallel so that the stray magnetic field from one circuit compensates that from the other. These circuits should be as symmetrical as possible in all respects. Loop areas and turns should be equal so that equal currents are needed for compensation. Resistances should be equal so that currents will be equal.

Time constants should be equal so that currents in the two circuits rise and fall together at the beginning and end of a sweep pulse. If this condition is not satisfied, we will have compensation when the currents in the two circuits reach their steady-state values, but will lack compensation during the transients at the beginning and end of a sweep pulse. Careful design and workmanship are needed to make sure that the currents in the two parallel circuits are equal when the equipment is built, and that everything possible has been done to make sure that this condition will not change in the course of time. 5.7.2 Precaution to minimize the eff ects of un equal current division.

In addition to doing everything possible to ensure equal current division between parallel circuits, the equipment should be designed and built to minimize the effects of unequal current division if it occurs. For example, cable runs are twisted for this purpose (see 6.2.3); the folded design of disconnect switches minimizes the bad effect of unequal current division (see 6.4.8); and proper design of generator brush rigging gives current loops that have zero net magnetic moment regardless of whether the total armature current of the generator is or is not equally divided between the brush sets connected in parallel (see 7,3). 77