Downloaded from https://www.everyspec.com G MIL-HDBK-1001/l 5.2.6 Securing Emer~encv Exit Doors MIL-HDBK-1190 and MIL-HDBK-1OO8, ~ ~ Desire and Co struction require that emerzencv exit doors conform to the requirements of National Fire Protection Asso~iat~on (NFPA) 101, Code for Safet~ to Life from Fire in Buildings and Structures. Refer, also to NFGS-O871O, Finish Hardware, for criteria on door hardware.
In addition, the designer must ensure that the securing of emergency exit doors conforms to any specific functional requirements Emergency egress should normally be provided from higher restricted to lesser or unrestricted spaces Floor plan configurations or arrangements which provide for emergency egress from unrestricted or lesser restricted to higher restricted spaces shall be avoided. Emergency exit doors from restricted or unrestricted rooms should be capable of rapid opening from the inside , and should not be operable from the outside. 5 .2.6.1 Floor Plan. Ideally, the emergency exit doors should be located within view of a work or duty station.
When this is not feasible, proper exit signage must be used. ,. 5 .2.6.2 Door Hardware. To avoid the use of exit devices (panic hardware) which tend to compromise security, use equivalent capacity single exit doors with locksets in preference to double doors. When single exit doors are not feasible, specify an Underwriters Laboratories, Inc. (UL) removable mull iOn (to facilitate the passage of lirge items) in conjunction with a pair of rim-type exit devices for exterior double door openings. This hardware is G recommended in lieu of vertical rod exit devices It is recommended that exit devices be provided of the type that do not require outside hardware.
Specify exit devices when required by NFPA 101 for public assembly or educational occupancy classifications where occupancy exceeds 50 persons As an aid to security, it should be noted that under certain conditions exit doors may be locked during periods of non-use, 5.2.6.3 Intrusion Detection Devices. Intrusion detection devices detect or restrict the unauthorized use of emergency exit doors , provide a high degree of control over the use of emergency exit doors , and provide constant surveillance in areas not feasible for security guards to patrol.
The following types of detection devices are available and are designed to be used in conjunction with emergency exit doors without impeding or preventing emergency use. a) Exit Alarm. This self-contained alarm is installed on an interior wall beside a doorway or on the interior surface of the door. The alarm is equipped with high-decibel horns which are triggered by a mechanical actuator or electrical triggering device. Authorized personnel with special keys can enter and exit the door without triggering the alarm. Exit alarms generally are the most economical anti- intru=~on d=vices b) Panic and Alarm Hardware.
Panic and alarm hardware is a combination of panic hardware and an exit alarm which permits instant by pushing a bar that allows a deadlocking latch-bolt to withdraw and :0 ~-.-.. 13