EPSON — Error Messages

Troubleshooting 144 Error Messages Cause Action Piece fault. The fabric to be printed on is not affixed to the belt. There is an abnormality or fault on the surface of the fabric. Check the fabric, and remove any folds or bulges. Remove the fabric and install it again. Check piece fault excluded The foreign material detection sensor is disabled. Enable the foreign material detection sensor. It is dangerous to print with the foreign material detection sensor disabled. If an abnormality occurs in the fabric, or if the fabric is not affixed to the belt, the print heads could be damaged. Printing suspended Printing was paused by request.

Remove the cause for pausing the printer, and then click "Start" to restart printing. Head height incorrect The head height is incorrect. Check the setting value. Piece too tall The fabric height is incorrect. Check the setting value. Initial design position too small The print data setting is incorrect. Increase the value for "Start printing". Head not in safe position. The print heads are not in the correct position. Contact qualified service personnel for assistance. CARRIAGE. carriage linear motor: Servoerror The position of the print heads is not recognized due to a mechanical impediment. Press an "Emergency stop button". Turn off the power to the machine. Remove the cause of the fault.

Turn on the power to the machine. CARRIAGE. carriage linear motor: encoder connection incorrect The print heads were moved by hand. CARRIAGE. carriage linear motor: movement not completed The print heads cannot move to the specified position due to a mechanical impediment. BELT. belt drive motor: Servoerror The position of the belt is not recognized due to a mechanical impediment. BELT. belt drive motor: encoder connection incorrect The belt was moved by hand. BELT. belt drive motor: movement not completed The belt cannot move to the specified position due to a mechanical impediment.

"xx-x" albre receiver disconnected One or more devices have been disconnected from the internal system network. Press an "Emergency stop button". Turn off the power to the machine. Check the connection of the network cable. Turn on the power to the machine. "xx" albrem receiver disconnected "x" albstep receiver disconnected