EPSON — EVO TRE 8

Specifications Power EVO TRE 8 Factory facilities 34 Item Specifications Notes Voltage 400 V ± 10 %, 3-phase + Neutral + Earth Frequency 50 / 60 Hz ± 3 % Power consump- tion 20 KVA Leakage current 300 mA or less Factory facilities Connected/Wired Type: Terminal block connection Connecting part model: CBD 16 (Manufacturer. by Cabur) Compatible crimped terminals (reference): Ferrule type WP160/22 Wiring specifications (recommended): 600 V pressure resistance (UL1063 equivalent) Wire size of AWG12 or larger Item Specifications Notes Electrical power See "EVO TRE 8" on page 34. Pressurized air Connector: Connect with a Φ8 mm (ext. diam.) hose Pressure: Min. 0.6 MPa (6 bar) Flow rate:

400 Liter/hr Required for raising/lowering the cleaning tank, ink pressure, etc. Water Connector: 3/4 gas Pressure: Max. 0.5 MPa (5 bar) Flow rate: Max. 100 Liter/hr {6,102 in3/h} Required for belt cleaning. Wastewater Connect with a Φ40 mm (ext. diam.) pipe Required for wastewater for belt cleaning. Users are requested to dispose of wastewater according to local laws and regulations. Waste liquid Flushing area Outer diameter of ink discharge outlet: Φ20 mm Applicable inner tube diameter: Φ19 mm Waste ink is discharged from the flushing area and cleaning station, and therefore it is neces- sary to provide a route for waste liquid in the factory's drainage system.

Users are requested to dispose of waste ink according to local laws and regulations. Cleaning station Outer diameter of ink discharge outlet: Φ40 mm Applicable inner tube diameter: Φ38 to 39 mm Exhaust Connector: Φ 125 mm Flow rate: 1,200 m3/hr {73,228,493 in3/h} Required for mist exhaust in the machine. If a 1,200 m3/h exhaust system is not avail- able, please provide a mist exhaust fan.