Mitsubishi — 5.1.3 Parameter list (by function group number)

5.1.3 Parameter list (by function group number)  E: Environment setting parameters 4  D: Parameters for the setting of operation command and frequency command Parameters for the inverter operating environment. 2 Parameters for setting the command source to the inverter, and the motor driving frequency and torque. 3 4 5 6 7 8 9  H: Protective function parameter 10 Parameters to protect the motor and the inverter.  F: Parameters for the settings of the acceleration/deceleration time and the acceleration/deceleration pattern Parameters for the motor acceleration/deceleration characteristics. 81 5. PARAMETERS 5.1 Parameter list Pr. group Pr.

Name Refer to page E000 168 Parameter for manufacturer setting. Do not set. E001 169 Parameter for manufacturer setting. Do not set. E023 269 Parameter for manufacturer setting. Do not set. E080 168 Parameter for manufacturer setting. Do not set. E081 169 Parameter for manufacturer setting. Do not set.

E100 75 Reset selection 85 E101 75 Disconnected PU detection 85 E102 75 PU stop selection 85 E103 145 PU display language selection 87 E104 990 PU buzzer control 87 E105 991 PU contrast adjustment 88 E200 161 Frequency setting / key lock operation selection 88 E202 40 RUN key rotation direction selection 88 E300 30 Regenerative function selection 159 E400 77 Parameter write selection 89 E410 296 Password lock level 90 E411 297 Password lock/unlock 90 E415 520 Parameter for manufacturer setting. Do not set. E600 72 PWM frequency selection 92 E601 240 Soft-PWM operation selection 92 Pr. group Pr.

Name Refer to page D000 79 Operation mode selection 100, 104 D001 340 Communication startup mode selection 104 D010 338 Communication operation command source 105 D011 339 Communication speed command source 105 D013 551 PU mode operation command source selection 105 D020 78 Reverse rotation prevention selection 108 D200 15 Jog frequency 108 D301 4 Multi-speed setting (high speed) 109 D302 5 Multi-speed setting (middle speed) 109 D303 6 Multi-speed setting (low speed) 109 D304 to D307 24 to 27 Multi-speed setting (speed 4 to speed 7) 109 D308 to D315 232 to 239 Multi-speed setting (speed 8 to speed 15) 109 Pr. group Pr.

Name Refer to page H000 9 Electronic thermal O/L relay 112, 147 H101 249 Earth (ground) fault detection at start 114 H104 631 Inverter output fault detection enable/disable selection 114 H105 598 Undervoltage detection enable/disable selection 115 H200 251 Output phase loss protection selection 115 H201 872 Input phase loss protection selection 115 H300 65 Retry selection 115 H301 67 Number of retries at fault occurrence 115 H302 68 Retry waiting time 115 H303 69 Retry count display erase 115 H400 1 Maximum frequency 117 H401 2 Minimum frequency 117 H402 18 High speed maximum frequency 117 H420 31 Frequency jump 1A 118 H421 32 Frequency jump 1B 118 Pr. group Pr.

Name Refer to page F000 20 Acceleration/deceleration reference frequency 93 F002 16 Jog acceleration/deceleration time 108 F003 611 Acceleration time at a restart 159 F010 7 Acceleration time 93 F011 8 Deceleration time 93 F020 44 Second acceleration/ deceleration time 93 F021 45 Second deceleration time 93 F100 29 Acceleration/deceleration pattern selection 95 F101 59 Remote function selection 96 F102 13 Starting frequency 99