Iveco — REPAIRING ACTIONS

S TRALIS AS E URO 4/5 114 F3A ENGINE Base - September 2006 Print 603.93.531 Actuator Figure 232 71834 1. Air inlet - 2. Gasket - 3. Piston - 4. External spring - 5. Internal spring control disc - 6. Internal spring - 7. O-ring - 8. Spring holder - 9. Limit stop - 10. Dust seal - 11. Control rod Figure 233 [bar] Stroke [mm] 72421 a Gradient characterized by the effect ofthe externalspring (4, Figure 232). b Gradient characterized by the effect of the external (4, Figure 232) and internal (6, Figure 232) springs.

Working principle (See Figure 232) The actuator piston, connected to the drive rod, is controlled with the compressed air introduced through the air inlet (1) on the top of the actuator. Modulating the air pressure varies the movement of the piston and turbine control rod. As the piston moves, it progressively compresses the external spring (4) until the base of the piston reaches the disc (5) controlling the internal spring (6). On further increasing the pressure, the piston, via the disc (5), interferes with the bottom limit stop (10). Using two springs makes it possible to vary the ratio between the piston stroke and the pressure.

Approximately 85% of the stroke of the rod is opposed by the external spring and 15% by the internal one. Solenoid valve for VGT control This N.C. proportional solenoid valve is located on the left-hand side of the crankcase under the turbine. The electronic control unit, via a PWM signal, controls the solenoid valve, governing the supply pressure of the turbine actuator, which, on changing its position, modifies the cross-section of the flow of exhaust gases onto the blades of the impeller and therefore its speed. The VGT solenoid valve is connected to the electronic control unit between pins C1 / C3. The resistance of the coil is approx. 20-30 Ohms.

REPAIRING ACTIONS NOTE If anomalous engine operation is found, which is due to the boosting system, it is advisable that you check the efficiency of seal gaskets and the fastening of connecting sleeves prior to carrying out the checks on the turboblower. Also check for obstructions in the sucking sleeves, air filter. If the turbocharger damage is due to a lack of lubrication, check that the oil circulation pipes are not damaged. If so, change them or eliminate the cause. After carrying out the above mentioned checks, check the turbocharger operation with an Engine Test by using IVECO diagnosis equipment (Modus - IT 2000 - E.A.SY.) according to the relevant procedure.

NOTE The test must be performed in following conditions: - engine coolant temperature >50 ºC; - battery up (voltage >22V) for compression test; - efficient recharging system. If values beyond tolerance are detected, check the efficiency of: - shut-off valve; - pressure sensor; - engine cable pressure sensor connection (if oxidised, clean with a specific product); - lack of electrical defects in solenoid valve VGT (continuity connection); - actuator moved by active diagnosis as described in relating chapter, in case of locking, grease bushing with lubricant Kernite (for high temperatures); if the trouble persists, replace the actuator; - sliding sleeve:

it must slide freely when operated manually. If locked and if the bush check is not sufficient or effective, or no faults are detected in the other points, upon authorization of the ”Help Desk” market operator, change the turbocharger according to the standard procedures.