BODY — Fronte-retro

SPECIAL INSTRUCTIONS FOR -SCR- EXHAUST SYSTEMS 6-15 E UROCARGO Euro 4/5 6.5.2.1 Instructions for lengthening and shortening the AdBlue ducts on the vehicle 1) Mark the delivery and returns ducts before separating them to ensure that they are correctly positioned during subsequent assembly. The maximum permitted length for ducts must not exceed 5 m from the reservoir to the supply module and 3 m from the supply module to the dosing module. 2) Cut the AdBlue duct (MLT Rehau - VOSS HWL 8.8 x 1.4 PA wall thickness 0.2 mm and 0.4 mm PA/PUR) with the appropriate pipe cutting clippers in order to ensure an accurate cutting area.

For reasons of space, it is advisable to divide the AdBlue delivery and return ducts along the length of the line. Figure 6.13 123261 3) The special band is pushed by the fitting toward the end of the pipe. 4) The pipe is inserted in the pipe jaws and secured by clips. The end of the duct should extend4-5 mmfrom theclips. Thetightening force must be adjusted using adjustment screw (A) (the distance of the jaws without the pipe must be approximately 1-2 mm). Figure 6.14 123262 5) Fit expanding pin (B) in the tool element and push the transport bar mechanically toward the pipe until the pin cone fits fully into the pipe. Then pull the bar back and remove the expansion plug.

Specifications for installation and removal Print 603.93.431 Base - January 2008 A