fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Hard disk drive (HDD) / solid state drive (SSD) 7.4.6 Replacing a 2.5-inch HDD/SSD module Customer Replaceable Unit (CRU) Hardware: 5 minutes Tools: Phillips PH1 / (+) No. 1 screw driver (if moving installation frame) V CAUTION! Only remove an HDD/SSD module during operation if the drive is not currently being accessed. Observe the indicators for the corresponding HDD/SSD modules, see section "Indicators on the hot-plug HDD/SSD module" on page 426 . An HDD/SSD module can be replaced while the system is in operation. RAID configuration with a RAID controller: Modular Host Bus Adapter with "Integrated RAID" (IR). RAID levels 0 and 1 are supported for internal HDD configurations.

Modular RAID 0/1 controller with "MegaRAID functionality" (integrated MegaRAID). RAID levels 0, 1,10,5 and 50 are supported for internal HDD configurations. Modular RAID 5/6 controller with "MegaRAID functionality" (MegaRAID). RAID levels 0, 1, 10, 5, 50, 6 and 60 are supported for internal HDD configurations. As an option, a flash backup unit (FBU) can save the memory content even if the power fails. Cache memory size of up to 8 GB is available. RAID configuration without a RAID controller: Please follow the instruction of each software e.g. VSAN, Storage Spaces, and Storage Spaces Direct, provided separately to use the software RAID function of OS or Hypervisor.

All HDD/SSD modules (drives) must be uniquely identified so that they can be reinstalled in their original bays later. If this is not done, existing data can be lost. RX2530 M4 Upgrade and Maintenance Manual 161