fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Hard disk drive (HDD) / solid state drive (SSD) 7.4.6.1 Preliminary steps К "Locating the defective component" on page 48 К "Locating the defective server" on page 47 7.4.6.2 Removing the defective 2.5-inch HDD/SSD module К Remove the HDD/SSD module, see section "Removing 2.5-inch HDD/SSD modules" on page 159 . К If applicable, remove the HDD/SSD from the installation frame, see section "Handling HDDs or SSDs without installation frame" on page 131 . 7.4.6.3 Installing the new 2.5-inch HDD/SSD module К If applicable, install the HDD/SSD in the installation frame, see section "Handling HDDs or SSDs without installation frame" on page 131 .

К Install the HDD/SSD module, see section "Installing 2.5-inch HDD/SSD modules" on page 156 . 7.4.6.4 Concluding steps К If the HDD/SSD is configured using a RAID controller with a RAID level higher than "0", the rebuild will start automatically, see section "Performing a RAID array rebuild" on page 99 . 162 Upgrade and Maintenance Manual RX2530 M4