fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Basic hardware procedures 4.1.2 Determining the error class The Local Service Concept (LSC) allows you to identify defective server components. Failure events are assigned to one of two error classes: Global Error (for non CSS components) events that need to be resolved by maintenance personnel Customer Self Service (for CSS components) error events that may be resolved by operating personnel The Global Error indicator and the CSS indicator can be found on the front side and the rear side of the server. I In same cases the indicator on the rear is designed as a combined indicator (Global Error, ID and CSS indicator).

I The indicators also light up in standby mode and after a server restart due to a power failure. К Check the Global Error indicator and the CSS indicator. 4.1.3 Locating the defective component After determining the error class by the CSS indicator or the Global Error indicator (see section "Determining the error class" on page 48 ), indicators on the components and onboard indicators on the system board allow you to identify the defective component. I For more information, see the "ServerView Suite Local Service Concept (LSC)" manual.

Possibilities to get more information about the defective component Checking the ServerView System Monitor, available on Windows or Linux based servers with ServerView agents installed. I For more information, see the "ServerView System Monitor" user guide. Checking the System Event Log (SEL), see section "Viewing the SEL" on page 95 . Checking the indicators on the components, see section "Connectors and indicators" on page 415 . 48 Upgrade and Maintenance Manual RX2530 M4