Basic hardware procedures Example HVDC PSU 380 V V CAUTION! The HVDC PSU adjusts automatically to any power voltage in the range from 200 V – 380 V. You may only operate the server if its rated voltage range corresponds to the local mains voltage. A B Figure 17: Connecting the server to the DC voltage - example HVDC PSU 380 V К Push the power cord plug into the PSU connector until it clicks in. The nose of the power cord plug (A) engages in the recess of the PSU connector (B). К Ensure that the status indicator on the PSU is lit green, see section "Indicators on PSUs (hot-plug PSUs)" on page 431 . К If necessary, make a permanent connection to the distribution board. V CAUTION!