fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Basic hardware procedures 4.6.2 Connecting the power cord (DC PSU) Example DC PSU -48 V V CAUTION! The DC PSU adjusts automatically to any power voltage in the range from -40.5 V - -57 V. You may only operate the server if its rated voltage range corresponds to the local mains voltage. Figure 16: Connecting the server to the DC voltage - example DC PSU -48 V К Connect the power cord to the PSU (1). К Fasten the two screws (2). К Ensure that the status indicator on the PSU is lit green, see section "Indicators on PSUs (hot-plug PSUs)" on page 431 . К If necessary, make a permanent connection to the distribution board. V CAUTION!