fujitsu RX2530 M4 — FUJITSU Server PRIMERGY RX2530 M4

Basic software procedures 5.2.7 Resetting the error status after replacing memory modules or CPUs 5.2.7.1 Memory modules ServerView Operations Manager may report a defective memory module in case of a memory error. I Important note After replacing a defective memory module, please check if the error counter has been reset automatically. If the memory slot is still marked as failed, please reset the error counter manually using one of the methods below. Using ServerView Maintenance Tools (Windows only) К Launch the ServerView Maintenance Tools: Start > Apps > Fujitsu > Maintenance Tools К Choose the Memory status tab. К Select the memory module which shows the pre-failure status.

К Click on Reset Status . I The Reset Status button will only be available if the selected memory module contains errors. К Ensure that all pre-fail/fail status issues have been resolved in ServerView Operations Manager. Using the command line interface (Linux/VMware only) The memory error counter can be reset using the meclear utility which is part of the ServerView agents for Linux. I meclear (Memory Module Error Counter Reset Utility) allows to reset the error count collected for a memory module, for example after it has been replaced. For more Information, see the meclear manual pages. К Log in as root. К Enter the command below, followed by [ENTER] :

/usr/sbin/meclear 90 Upgrade and Maintenance Manual RX2530 M4