Basic software procedures К Select the number of a memory module with a status other than "OK" or "Not available". К Repeat the step above until all memory modules show the "OK" status. К Ensure that all pre-fail/fail status issues have been resolved in ServerView Operations Manager. 5.2.7.2 CPUs ServerView Operations Manager may report a defective CPU in case of a critical error. I Important note After replacing a defective CPU, the error counter must be reset manually using one of the methods below. Using ServerView Maintenance Tools (Windows only) К Launch the ServerView Maintenance Tools: Start > Apps > Fujitsu > Maintenance Tools К Choose the CPU status tab.
К Select the CPU which shows the pre-failure status. К Click on Reset Status . К Ensure that all pre-fail/fail status issues have been resolved in ServerView Operations Manager. Using the command line (Linux only) Proceed as follows to reset the error counter of a specific CPU: К Enter the command below, followed by [ENTER] : К Log in as root. For rack and floorstand servers (RX and TX server series): /usr/sbin/eecdcp -c oc=0609 oi= For blade and scale-out servers (BX and CX server series): /usr/sbin/eecdcp -c oc=0609 oi= cab= To identify the cabinet number, enter the following command: /usr/sbin/eecdcp -c oc=E204 RX2530 M4 Upgrade and Maintenance Manual 91