Downloaded from https://www.everyspec.com AMCP 706.210Ei9 iiT 777 _:I- A ~ A MBER Figure, 15-13. Vacuum 'Stiam Pressure Chamber i the waterpirooffress test, (MIL-STD-331,? The thermal shock!,tes, (MIL-STD-331,,,Test, Test 108)i fuzes are immersed ir 'iuater to' de: 1.13), consists of. subjecting, the fuze-totheima1. termine their. ability to witlutand' water pen& shocks (three hot and three bdold).I betivee n the traio.Afer~akngforonhor..inwaterconi-t4emperatures of m650 .and.1 ~ 0 'wti ors taing -a fluorescent dye,, they are examined to determine, whether 4he ;fuz~s will Withstand under ultx~violetlight-'for i'vidence of moisture. the" effects of, sudden chang~s, in tempe Irature..

'The 4 rain exposure 'test (MIL-STD-81,, Test' In addition to these~rfior6 common tests, 4 the 109) is intended to simulate field opeiati6ns to fuze may be subjected to other ernJrormenta 'vhichr'tf6 'fuze ffmight be subjedted during stor- conditions that it.ffmay eicounter; e.g., the cold age in rainy w eather. Thd test consists of placing andres'othplrrgosaidheow bare fuzes in a 'test' chamber wher6.a-water dis- 'pressure, cold air .;treams at high altitude. Pro- tribUtion system, generally simulating rainfall, cedures a&~ &viiAble 'to test effectsof sand andI causes droplets to fall upon. the, test fuzes.

dust, solar radiation, low pressure, and ,sensi- The fungus resistanke test (MIL-STD-331,, Test tivity of the fa.ze to rainfall'. A~numberof rain, '110) consists ~of exposing bare, fuzes inoculated simulation techniques have 'been develkiped'; 4 with fungi to conditions con ,ducive to fungus description of'a'sihiulated rain field'testfacility growth 'to detini-ne if fuze performance is ad- follows 7 . versely affected by 'this environment.

The ap- A simulated rain~ field',(iocated at Holloman pearance 'of fungi on the fuze is not in itself'a Air 'Force Base, Alamogordo, New Mexico) has cause for rejection, unless thegrowth could con- been successfully used in testing for rain,sensi- ceivably interfere with the safety and operability' tivity and erosion of point-detonating fuzes. oftefuze. :nti eret'h~test'differs from. Functioning of various sta idard PD fuie& (not tests designed to evaluate fungus resistance pro- desensitized against rain functioning), has been perties as such. induced by firing the fuzes from cannon or by' 15-12