U.S. Army Material Command (AMC) AMCP 706-210 — FUZES - Engineering Design Handbook AMCP 706-210 (U.S. Army) PDF Download

Downloaded from https://www.everyspec.com AMCP 706-210 TABLE 4-2.

COMPATIBILITY OF COMMON EXPLOSIVES AND METALS Lead Lead Azide Styphnate PEN 7W HX Tetryl Magnesium N B N S Aluminum A N A N A N VS A N VS A N Zinc C N A B VS Iron N A B S Steel C N B N VS AVS S C H Tin AN A AN Cadmium C A Copper D N A B N VS A S S AN Nickel C A AN Lead N A A N Cadmium plated steel B N S VS VS A N Copper plated steel N B N VS B VS VS A VS Nickel plated steel N B N VS A N S A N Zinc plated steel N B N VS A N S AN Tin plated steel N A B VS Magresium aluminum VS B N S Monel Metal C N Brass DN B NS AS S B VS Bronze N A A VS 18-8 stainless steel A N A ANN A N N A N Titanium N N N Silver N N N CODE A no reaction H heavy corrosion of metals B slight reaction VS very slight corrosion of metals C reacts readily S slight corrosion of metals D reacts to form sensitive materials N no corrosion (6) Avoid flame- and spark-producing equip- (1) Consult the safety regulations prescribed ment.

by the military agency and by the local and (7) Keep to a minimum the number of per. Federal Governments. sonnel at work in the same area, but one man (2) Conduct all experiments in the prescribed should never work alone. laboratory space, never near storage spaces of (8) Be sure that the chamberm for "loading" bulk explosives. and "exploding" are well shielded electrically (3) Experiment with the smallest sample of and mechanically. explosive that will answer the purpose. (9) Some explosive materials are stored wet, (4) Keep all work areas free from contami- some dry, and some in special containers. In- nants.

sure that the special requirements for each type (5) Avoid accumulation of charges of static are complied with in full. 4-2.4.1 General Rules for Handling Explosives electricity. 4-4