HP — Continuable and Non-Continuable Error Codes

Problem Description: Aerosol Fan not connected. Corrective Action: Try the following: • Check that the Aerosol Fan cable is not damaged and is correctly connected to the Interconnect PCA. • Replace the Aerosol Fan ⇒ Page 300. System Error Codes System Error: 46:03 Problem Description: Primer servo shutdown. Corrective Action: Try the following: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Replace the Primer Assembly ⇒ Page 294. • Replace the PrintMech PCA ⇒ Page 384. • Replace the Interconnect PCA ⇒ Page 357. System Error: 46:10 Problem Description: Electrical fault in primer motor. Corrective Action:

Try the following: • Switch the Power OFF from the back of the Printer and disconnect the Power cord. Reconnect the power cord and power On the Printer. • Replace the Primer Assembly ⇒ Page 294. • Replace the PrintMech PCA ⇒ Page 384. • Replace the Interconnect PCA ⇒ Page 357 System Error: 46:13 Problem Description: Primer test distance failed. Corrective Action: Try the following: • Check that the Primer Arm is not damaged and there are no obstacles in its way. 62 Chapter 2 System Error Codes