H8DCL-6/i(F) SERVERBOARD USER'S MANUAL 3. Align pin 1 of the CPU with pin 1 of the socket. Once aligned, carefully place the CPU into the socket. Do not drop the CPU on the socket, move the CPU horizontally or vertically or rub the CPU against the socket or against any pins of the socket, which may damage the CPU and/or the socket . 4. With the CPU inserted into the socket, inspect the four corners of the CPU to make sure that it is properly installed and fl ush with the socket. Then, gently lower the silver CPU retention plate into place. 5. Carefully press the CPU socket lever down until it locks into its retention tab.

For a dual-CPU system, repeat these steps to install another CPU into the CPU#2 socket (and into CPU#2, #3 and #4 sockets for a quad- CPU confi guration). Installing the Heatsinks We recommend the use of active type heatsinks (except for 1U systems). Use any onboard fan header for the CPU's heatsink fan. To install the heatsink, please follow the installation instructions that are included with your heatsink package. Note: Make sure the heatsink is placed so that the fi ns of the heatsink are in the direction of the airfl ow in your system. 2-6