Supermicro H8DCL-6/i(F) — Supermicro H8DCL-6/i(F) Serverboard User's Manual PDF

Chapter 2: Installation Power Fail LED The Power Fail LED connection is located on pins 5 and 6 of JF1. Refer to the table on the right for pin defi nitions. Connect an LED to the OH connection on pins 7 and 8 of JF1 to provide advanced warning of chassis overheating or fan failure. Refer to the table on the right for pin defi nitions and status indicators. Overheat/Fan Fail/UID LED NIC2 (Activity) LED The LED connections for LAN2 are on pins 9 and 10 of JF1. Attach LAN LED cables to display network activity. See the table on the right for pin defi nitions. NIC1 (Activity) LED The LED connections for LAN1 are on pins 11 and 12 of JF1. Attach LAN LED cables to display network activity.

See the table on the right for pin defi nitions. HDD LED The HDD LED connection is located on pins 13 and 14 of JF1. Attach the hard drive LED cable here to display disk activity (for any hard drives on the system, including SAS, Serial ATA and IDE).

See the table on the right for pin defi nitions 2-13 PWR Fail LED Pin Defi nitions (JF1) Pin# Defi nition 5 3.3V 6 Power Fail LED OH/Fan Fail LED Pin Defi nitions (JF1) Pin# Defi nition 7 Vcc 8 OH/Fan Fail (Red)/ UID (Blue) LED OH/Fan Fail LED Status State Indication Solid Overheat Blinking Fan fail NIC2 LED Pin Defi nitions (JF1) Pin# Defi nition 9 Vcc 10 Activity NIC1 LED Pin Defi nitions (JF1) Pin# Defi nition 11 Vcc 12 Activity HDD LED Pin Defi nitions (JF1) Pin# Defi nition 13 Vcc 14 HDD LED