omron — Back Up / Restore / Capture the OS Image with Microscan Rescue Utility

Appendix G Operating System Save and Restore Capture OS To customize your unit and deploy the same configuration to other HAWK MV-4000 cameras, do the following: 1. After the Out-Of-Box-Experience (OOBE) completes, switch to Audit Mode as soon as possible . This allows you to keep the multiple language capability on other units. To switch to Audit Mode, go to the OSConfig.exe > Capture OS tab and click the Reboot to Audit Mode button. 2. In Audit Mode, you are automatically logged on as the Local Administrator . You have full access to configure your system. Make sure the Unified Write Filter (UWF) is disabled so your settings can be saved.

While you are in Audit Mode, every time you reboot, the System Preparation Tool (Sysprep) windows will pop up. You can ignore it or click Cancel to close the window. 3. When you are done configuring your unit, go back to the OSConfig.exe > Capture OS tab and click the Reboot and Launch Capture Tool button. Before launching the System Preparation Tool (Sysprep) to reseal the image, it will delete the msuser account, click OK to continue. The system will reboot and run Sysprep to reseal the image. When this is done, it will reboot to System Recovery Options . 4. After your PC restarts to the Choose an Option screen, select Troubleshoot > Omron Microscan Rescue Utility . 5.

After accepting the License Agreement, the windows will show up with option already selected: Capture the OS for Deployment . 6. Select the location of the USB device to save the captured OS. Warning: This will reformat the USB device and all data will be erased. The utility will configure the USB device to be bootable with all necessary settings to restore your customized image to other HAWK MV-4000 units. G-18 HAWK MV-4000 Smart Camera Guide