Hantek — 10.6 Trigger Source

Burst EN available for N Cycle burst in internal trigger. The default is 10 ms. ⚫ Burst period ≥ 1μs + Carrier Waveform Period Ч Burst Count. ⚫ If the burst period is set to too small, the generator will increase this period Press [Burst] > Type softkey to select N Cycle . Press Trig Src softkey and select automatically to allow the output of the specified number of cycles. Internal, then press Period softkey, and use the numeric keypad or direction keys and the knob to input the desired period. The default value is 10ms and the settable range is 2μs to 500s. This menu will be grayed out and disabled when the burst type is set to Infinite cycle or Gated.

10.5 Burst Phase Burst phase is defined as the phase of the start point of the burst. When Burst is enabled, press Phase softkey and use the numeric keypad or direction keys and the knob to input the desired phase. The default value is 0° and the settable range is 0° to 360°. ⚫ For Sine, Square, Ramp and Pulse, 0° is the point where the waveform passes through 0V (or DC offset value) positively. ⚫ For arbitrary waveform, 0° is the first point of the waveform. ⚫ For Noise, Start Phase is unavailable. 10.6 Trigger Source Burst trigger source could be internal, external or manual.

The generator will generate a burst output when a trigger signal is received and then wait for the next trigger When Burst is enabled, press Trig Src softkey to select " internal ", " external " or " manual ". The default setting is "Internal". Internal Trigger When internal trigger is selected, the generator can only output N cycle burst and the burst frequency is determined by the "Burst Period". External Trigger When external trigger is selected, the generator can output N cycle, infinite or gated burst. The generator receives the trigger signal from the [FSK/Trig/Sync/Extmod] connector on the rear panel.

A burst will be generated once the connector receives a TTL pulse with specified slope or polarity. To set the extrenal trigger slope, press Slope softkey to select "Rising" or "Falling" and the default is "Rising". Manual trigger When manual trigger is selected, the generator can output N cycle or infinite burst. A HDG3000C User manual Copyright © Qingdao Hantek Electronics Co., LTD 66