Run all Once the test sequence is complete, the ‘cycle complete’ LED turns ON. If no errors were detected, then all ‘cycle length’, ‘progress status’, and ‘warning’ LEDs are OFF, as is the ‘error’ LED. If an error was detected, then the ‘cycle length’, ‘progress status’, and ‘warning’ LEDs display an error code. The ‘cycle complete’ LED is OFF while the ‘error’ LED blinks. Interactive mode After each subtest completes, the ‘cycle length’, ‘progress status’, and ‘warn- ing’ LEDs momentarily turn OFF while the ‘cycle complete’ LED turns ON. Note that the ‘cycle complete’ LED is green, but is co-located with the left most ‘progress status’ LED (yellow).
The ‘cycle length’, ‘progress status’, and ‘warning’ LEDs continue to indicate the subtest that is selected; they do not update unless the ‘load select’ (or ‘start’) button is pressed. After the last sub- test, pressing ‘load select’ returns the ‘cycle length’, ‘progress status’, and ‘warning’ LEDs to all OFF. If a failure was detected in interactive mode, then the ‘error’ LED blinks and the ‘cycle complete’ LED is OFF while the ‘cycle length’ and ‘progress status’ LEDs display an error code. Note that the ‘error’ LED is red, but is co-located with the ‘warning’ LED (yellow). Subtest details LED subtest Two of the LED locations are bi-color LEDs.
These two are easiest to verify if only one of each pair of LEDs within the package is turned on at a time dur- ing testing. The LED test sequence is as follows: first, turn on all yellow LEDs (‘cycle length’, ‘progress status’, and ‘warning’) ON for ~2 seconds, turn those OFF while simultaneously turning the green and red LEDs (‘cycle com- plete’ and ‘error’) ON for ~2 seconds, then all LEDs OFF for ~2 seconds. Repeat that ON/OFF cycle once more. Return LEDs to proper state for next subtest (both ‘cycle load’ LEDs ON, etc.). This should allow support engineers sufficient time to verify that all LEDs can turn both ON and OFF.
Electronics Selftest This subtest is performed at any power-up to normal mode as well as during the diagnostic test sequence. This subtest should perform an internal check of any and all possible electronic circuits than can be verified automatically. Inlet Valve subtest This subtest opens (default state is closed) and then closes the water inlet valve at a 2 Hz. rate for a total of 5 cycles. This should allow support engi- neers an opportunity to hear the valve functioning. The valve must be left in the default state at the end of the subtest. If the system is connected to a water source, some water will enter the cleaning tank assembly during this subtest. 29