4. Using a #2 phillips screwdriver, remove 3 locking screws that attach the back panel to the upper housing See Figure 19 . Figure 19: Back panel screw locations Remove 3 locking screws 5. Tilt the back panel to gain access the connectors. Be careful not to put stress on any wire cables. 6. Disconnect the following cable connectors from the main control board: (see Figure 20 ) • P10 Power Cable (PN 208700) • P8 Motor Power (PN 208709) • P7 Inlet Valve (PN 208701) • P6 Drain Valve (PN 208702) • P1A Heater (PN 208723) (black wire) • P1B Heater (PN 208723) (white wire) • P5 Data Cable (PN 208726) • P4 Level Sensor (PN 208725) 7. Remove 1 grounding screw and remove 2 green grounding wires.
See Figure 20 . 40