Major Codes with Minor Codes NOTE: Currently minor codes exist for major codes 14, 15 17-20, 22, & 23 only. Controller Abort Minor Errors (Code: 14, XX) -90 Code Description Corrective Actions 14,01 Not Used Not Used 14,02 Report: Attempt to raise modeling base sensor failed 1. Cycle power 2. Check to see if the toggle bar is broken. 3. Check for obstructions preventing X or Y movement 4. Check the substrate sensor bar is not damaged. If so, replace bar. 5. Using LED's check to see if Z foam box toggles when switch is activated. If not, check foam sensor and/or Umbilical Cable. 6. Check for loose pins on J506-2, J506- 7, J301-5, and J301-6. See “Umbilical cable diagram” on page 129. 7.
Using LED's check to see Z home box toggles when switch is activated. If not, check Z home switch and/ lower harness J8 pins 1,11,12. See “Lower harness” on page 133. 14,03 Report: modeling base sensor up when it should be down. 1. Cycle power. 2. Check the substrate sensor assembly for free operation. 3. Check to see if the sensor arm is broken. 4. Check connector J506, pins 2 and 7 on the I/O card. 5. Using LED's check to see Z foam box toggles when switch is activated. If not, check substrate sensor, sensor assembly and/or lower harness. 14,04 Report: modeling base sensor down when it should be up. 1. Push the sensor assembly up if it is down. 2.
Check to see if the tip-wipe brush is set too high. 3. Run the FZ command using Tera Term -Verify the sensor is being pushed all the way up. 4. Remove, clean and reinstall the substrate sensor assembly.