HP — Major Codes with Minor Codes

-91 Code Description Corrective Actions 14,05 Abort : Unexpected contact with X axis home sensor. 14,06 Abort : Unexpected contact with X axis EOT sensor. 14,07 Abort : Unexpected contact with Y axis home sensor. 14,08 Abort : Unexpected contact with Y axis EOT sensor. 1. Power cycle the machine. 2. Check for an obstruction hitting the model. 3. Check to make sure the homing sensors are clean. 4. Using LED's check if home & limit boxes are lit. If so, check limit switches and/or Umbilical Cable for X sensors, Y cable for Y sensors. 5. Manually move the XY table in X and Y checking for smooth operation. 6. Check belt tension. 7. Replace XY table.

Failed bearings in the Y drive shaft possible root cause 14,09 Abort : Unexpected contact with Z axis home sensor. 14,10 Abort : Unexpected contact with Z axis EOT sensor. 1. Check to see if the switch is operating correctly using the LED/test points on the PDB. 2. Check to see if there are any obstructions interfering with Z stage movement. 14,11 Abort : Door opened while axis in motion 1. Check to see if door latch is activating using LED's. 2. Check J504 pins 8 and 20 on the I/O card for loose contacts or bent pins. 3. Look at LCD display, should show "Door Open" when machine is idle and door is open. 4. Using LED's check to see "Door Open" toggles when switch is activated.

If not, check door switch and/or Mid-Unit Harness. 5. Wiggle the door, make sure the sensor reads the magnet with movement to the door. 6. Check that the door magnet is present. 14,13 Abort : Under Run at vertex buffer 14,14 Abort : Under Run not in tool path 1. Reprocess the part and send again. 2. Reorient the STL and resend. 3. If the frequency of the error is greater than once every three months, then replace the SBC or hard drive. 14,15 Report: Head motor running without XY motion 1. Software use only. 14,16 Abort : Vertex FIFO tail is not on a 4 byte boundary. 1. Communication error between controller board and the SBC - Power cycle system 2. Reseat the controller board into SBC. 3.

Replace controller board and/or SBC. 14,17 Abort : User abort. 1. Build was cancelled through the keypad. 14,18 Abort : User panic stop. 1. Will not be displayed on LCD (Opening door during build can cause this error).