-92 Code Description Corrective Actions 14,19 Abort : Idle loop is slow. 1. Power cycle machine. 2. Escalate the case providing the .cfg file. 14,20 Abort : XY axis not ready. 14,21 Abort : Z axis not ready. 1. Power cycle machine. 2. Using the Tera Term, type SS. "X Axis Ready" should be displayed. If it is not displayed, then type the "FH" & "FZ" commands. Finally type "SS" again. If "X Axis Ready" still is not displayed, then replace the controller Board. 14,22 Abort : Head temperature set-point too low. 1. Reinstall printer firmware. 2. Verify the head temperature set point using HP Designjet 3D Diagnostic Software. • The model must be above 240 degrees.
• The support must be above 240 degrees. 14,23 Report: Begin curve parameters not in sequence. 1. Communication error between controller board & SBC - Cycle power 2. Reseat the controller board into SBC. 3. Replace controller board and/or SBC. 14,24 Abort : X axis command error (PMD error) 14,25 Abort : Y axis command error (PMD error) 14,26 Abort : Z axis command error (PMD error) 1. Power cycle machine. 2. If error continues - possible memory problem, replace SBC. 3. If the frequency of the error is greater than once every three months, replace the controller board. 14,27 Abort : X axis motion error (PMD error) 14,28 Abort : Y axis motion error (PMD error) 14,29 Abort :
Z axis motion error (PMD error) 1. Power cycle machine. 2. If the frequency of the error is greater than once every three months, replace the controller board. 14,30 Abort : PMD axis command was not X, Y, or Z. 1. Power cycle machine. 2. Reinstall printer firmware. 14,31 Abort : Move absolute error. 1. Check and reseat connectors to the X and Y motors. 2. Check home and EOT switches for correct operation. Replace if defective. 14,32 Abort : PMD checksum error. 1. Power cycle machine. 2. Reinstall printer firmware. 3. If the frequency of the error is greater than once every three months, replace the controller board.