HP — Major Codes with Minor Codes

-93 Code Description Corrective Actions 14,33 Abort : Invalid being send to PMD chip. 1. Power cycle machine. 2. Reinstall printer firmware. 3. If the frequency of the error is greater than once every three months, replace the controller board. 14,34 Abort : Z axis table jammed Not used on HP Designjet 3D printers. 14,35 Report: Time out while loading carrier. 1. See Load Failed Section (K) in the Non-Error Code Section. 14,36 Report: Modeling material not moving in head. 14,37 Report: Support material not moving in head. 1. Check and reseat J506 and check pins 2, 3, 7 and 8. 2. If error continues, replace the controller board. 14,38 Abort : Hardware turned off power supply. 1.

Check and reseat connectors to controller board and PDB. 2. Replace the controller board. 3. Replace the PDB. 4. Replace umbilical cable. 5. Jumper the WDT to retrieve CFG to find additional errors. 14,39 Abort : Head thermocouple fault. 1. Verify ambient temperature is above 18° C (64.4° F). 2. Check thermocouple wire for damage. 3. Using a meter, check to see if thermocouple is open at head. 4. Check/reseat the connectors on the head board. 5. Open may be in umbilical head cable. Check and reseat J505 and check pins 7 and 17 on the I/O card. 6. Check and reseat J7 and check pins 7 and 10 on the T/C amp board. 7. Replace the toggle head assembly. 8. Replace TC Amp board. 14,40 Abort :

Chamber thermocouple fault. 1. Verify ambient temperature is above 18° C (64.4° F). 2. Check to see if chamber thermocouple is plugged in to the PDB. 3. Using a meter check if thermocouple is open. If so, replace thermocouple. 4. Check chamber thermocouple and wire for damage. 5. Verify chamber fans are on. If not on replace 24VDC power supply. 6. Replace chamber thermocouple. 7. Replace power distribution board.