HP — Major Codes with Minor Codes

-94 Code Description Corrective Actions 14,41 Abort : Motion command while door open. 14,42 Abort : Load cartridge while door open. 14,43 Abort : Modeling command while door open 14,44 Abort : Select head command while door open. 14,47 Abort : Tip wipe command while door open. 1. Check to see if door latch is activating using LED's. 2. Check J504 pins 8 and 20 on the I/O card for loose contacts or bent pins. 3. Look at LCD display, should show "Door Open" when machine is idle and door is open. 4. Using LED's check to see "Door Open" toggles when switch is activated. If not, check door switch and/or Mid-Unit Harness. 5.

Wiggle the door, make sure the sensor reads the magnet with movement to the door. 6. Check that the door magnet is present. 14,45 Report: Unable to write to model material guide tube. 14,46 Report: Unable to write to support material guide tube. 1. Try a different material spool. 2. Clean contacts on carrier and material bay with an eraser. 3. Replace carrier. 4. Replace material bay. 14,48 Abort : Vertex command error. 1. If this message is displayed on LCD ONLY, possible memory problem, replace SBC. If this message is not displayed on the LCD, (seen in cfg file), RAM is NOT the root cause. 2.

If the frequency of the error is greater than once every three months, replace the controller board. 14,49 Internal : PCode Error, Bad Curve. This error will not be displayed. Software development use only. 14,50 Internal : PCode Error, DY within curve. This error will not be displayed. Software development use only. 14,51 Abort : Model material not loaded. 14,52 Abort : Support material not loaded. 14,53 Abort : Model head motor not ready. 14,54 Abort : Support head motor not ready. 1. Reload material. Note: System is not recognizing that material is loaded.