HP — Major Codes with Minor Codes

-95 Code Description Corrective Actions 14,55 Abort : Find home failed, X home and X eot both on 14,56 Abort : Find home failed, Y home and Y eot both on 1. Power cycle machine - remember to move head away from switches. 2. X errors - Check pins and reseat connector J505 on the I/O Board. Y errors - Check pins and reseat connector J503 on the I/O Board. 3. Using LED's check to see if switch state toggles. If not, check sensor and/or umbilical cable for X and Y cable for Y. 4. Replace the head board for X errors and replace the Y sensors for Y. 14,57 Abort : Find home failed, X home timeout 14,58 Abort : Find home failed, Y home timeout 1.

Power cycle machine - remember to move head away from switches. 2. If chatter in motor, check motor and/or motor cable for Y, umbilical cable for X. 3. Check for obstacles obstructing X or Y movement. 4. Using LED's check to see that the state changes when sensor is activated. If not, check sensor and/or umbilical cable for X and Y cable for Y. 14,59 Abort : Find home failed, X home not tripped 14,60 Abort : Find home failed, Y home not tripped 1. Power cycle machine - remember to move head away from switches. 2. Using LED's check to see home toggles when sensor is activated. If not, check sensor and/or Umbilical Cable for X and Y cable for Y. 3.

X errors - Check pins and reseat connector J505 on the I/O Card. Y errors - Check pins and reseat connector J503 on the I/O Card. 14,61 Abort : Find home failed, X home tripped 14,62 Abort : Find home failed, Y home tripped 1. Power cycle machine - remember to move head away from switches. 2. Using LED's check to see home box toggles when sensor is activated. If not, check sensor and/or umbilical cable for X , Y cable for Y. 3. X errors - Check pins and reseat connector J505 on the I/O Card. Y errors - Check pins and reseat connector J503 on the I/O Card. 14,63 Abort : Find home failed, X eot tripped 14,64 Abort : Find home failed, Y eot tripped 1.

Power cycle machine - remember to move head away from switches. 2. Using LED's check to see home box toggles when sensor is activated. If not, check sensor and/or umbilical cable for X , Y cable for Y. 1. X errors - Check pins and reseat connector J505 on the I/O Card. Y errors - Check pins and reseat connector J503 on the I/O Card.