HP — Major Codes with Minor Codes

-96 Code Description Corrective Actions 14,65 Abort : Find home failed, X eot not tripped 14,66 Abort : Find home failed, Y eot not tripped 1. Power cycle machine - remember to move head away from switches. 2. Using LED's check to see home box toggles when sensor is activated. If not, check sensor and/or umbilical cable for X , Y cable for Y. 3. X errors - Check pins and reseat connector J505 on the I/O Card. Y errors - Check pins and reseat connector J503 on the I/O Card. 14,67 Abort : Head temperature too high 1. Verify the TC and Liquefier Heaters are plugged in properly. 2. Check umbilical is connected properly. 3. TC Amp board is bad. Replace TC Amp Board. 4. Head board is bad.

Replace head board. 5. Replace the umbilical cable. 14,68 Abort: Illegal PMD Command 1. If error occurs more than once a month replace the controller board. 14,69 Abort: XY PMD Read Checksum error 1. If error occurs more than once a month replace the controller board. 14,70 Abort: XY PMD Write Checksum error 1. If error occurs more than once a month replace the controller board. 14,71 Abort: Z PMD Read Checksum error 1. If error occurs more than once a month replace the controller board. 14,72 Abort: Z PMD Write Checksum error 1. If error occurs more than once a month replace the controller board. 14,73 Abort: Head TC Board Configuration error Not used on HP Designjet 3D printers.

14,74 Unexpected contact with unknown limit. 1. Power cycle machine - remember to move head away from switches. 2. Using LED's check to see limit box toggles when switch is activated. If not, check switch and/or umbilical cable for X, Y cable for Y. 3. X errors - Check pins and reseat connector J505 on the I/O Card. Y errors - Check pins and reseat connector J503 on the I/O Card. 14,75 Unknown No error code associated with an error. 14,76 Software bug 1. Cycle power. 14,77 Buffer is larger than the data 14,78 Buffer is smaller than the data 1. Cycle power. 2. Replace single board computer. 3. Replace controller board.