-97 Code Description Corrective Actions 14,79 Run-time error 1. Cycle power. 2. Check .cfg File for other errors. 3. Replace single board computer. 4. Replace controller board. 14,80 Index out of bounds 1. Cycle power. 14,81 Invalid argument 1. Cycle power. 14,82 Invalid channel 1. Cycle power. 14,83 Invalid command 1. Cycle power. 14,84 Invalid command opCode 1. Cycle power. 14,85 The operation is not implemented Software error; will not be displayed. 14,86 Timeout 1. Cycle power. 2. Replace controller board. 14,87 Resource already in use 1. Cycle power. 14,88 The dual-port memory is corrupted 1. Cycle power. 14,89 No valid ISR callback routine set 1. Cycle power.
14,90 An internal queue has overflowed 1. Cycle power. 14,91 Address not properly aligned 1. Cycle power. 14,92 Message too big for queue 1. Cycle power. 14,93 Data unit size violation 1. Cycle power. 14,94 Checksum bad 1. Cycle power. 2. Check 5/12 VDC power (5 and 12VDC LEDs will repeatedly dim). Replace 5/12 VDC power supply. 3. If error code is displayed again within 3 months, replace controller board. 14,95 PMD Host IO Error 1. Cycle power. 14,96 Unidentified interrupt occurred 1. Cycle power. 14,97 Invalid data type 1. Cycle power. 14,98 Find home failed, X EOT timeout 14,99 Find home failed, Y EOT timeout 1. Power cycle machine - remember to move head away from switches. 2.
Using LED's check to see limit box toggles when switch is activated. If not, check switch and/or umbilical cable for X, Y cable for Y. 3. X errors - Check pins and reseat connector J505 on the I/O board. Y errors - Check pins and reseat connector J503 on the I/O Card.