HP — Major Codes with Minor Codes

-98 Code Description Corrective Actions 14,100 Find home failed, Z HOME (BOT) not tripped 14,101 Find home failed, Z EOT not tripped 14,102 Find home failed, Z HOME (BOT) timeout 14,103 Find home failed, Z EOT timeout 1. Check for objects/parts on Z stage and around lead screw. 2. Cycle power. 3. Check Z Home and Z EOT LED's on PDB to verify state changes correctly. If not, check connector P8 on the PDB and Z switches. Replace cable and/or switches. 4. Replace Z axis motor and lead screw. 5. 14.101 error only - Check 5/12 VDC power (5 and 12VDC LEDs will repeatedly dim) Replace 5/12 VDC power supply. 14,104 Surface not found 1. No modeling base. 2.

Modeling base is used/defective, has low spot. Replace Modeling base. 3. Verify substrate sensor is working. If not, replace Substrate Sensor. 14,105 Controller not ready to build a model 1. Cycle power. 14,106 BOT offset is higher than the BOT switch 1. Use HP Designjet 3D Diagnostic Software to zero the Z offset value. 2. Run tip Z calibration. 3. Check Z home sensor. 14,107 End model command while not modeling Software error; will not be displayed. 14,108 Operation was killed Software error; will not be displayed. 14,109 Out of memory Software error; will not be displayed. 14,110 Cartridge communication error 1. Replace material spool. 2. Replace material carrier. 3. Replace material bay.

14,111 Invalid frame check sequence 1. Cycle power. 2. If error repeats, replace controller board. 14,112 EEPROM communication error Software error; will not be displayed. 14,113 Door not latched 1. Verify chamber fans are operational. If not replace 24VDC power supply. 2. Inspect solenoid and wiring. 3. Replace solenoid. 4. Replace PDB. 14,114 Thermocouple snap switch tripped Not used on HP Designjet 3D printers. 14,115 Z stage planarity beyond tolerance 1. Replace modeling base. 2. Re-level XY table. 14,116 I2C configuration info is corrupt Software error; will not be displayed.