-105 Code Description Corrective Actions 18,01 Chamber temperature too high (over 77 degrees) 1. Chamber TC has failed. Replace chamber TC. 2. Chamber temperature offset is incorrect. Correctly set at 77 degrees using HP Designjet 3D Diagnostic Software. See “Temperatures” on page 428. 18,02 Temperature failed to regulate within 7 degrees. 1. Status--Details: Check to see if head temperature set point is 310C for model and 300C for support. 2. Check Liquefier Thermocouple wire and/or Heater wires. 3. Check for torn or damaged insulation on the liquefier, especially at the tip. 4. Check head T/C and umbilical cable for a loose connection. Replace umbilical cable.
18,03 Incorrect model head temperature. 1. Using HP Designjet 3D Diagnostic Software, set model temperature to default of 310C. 2. See also 18,01. 18,04 Incorrect support head temperature. 1. Using HP Designjet 3D Diagnostic Software, set support temperature to default of 300C. 18,05 Incorrect chamber temperature. 1. Using HP Designjet 3D Diagnostic Software, set chamber temperature to default of 77C.