Controller Initialization Failed Minor Errors (19.XX) Door Unlatch Failed (20.XX) Controller Communications Failed Sub Errors (22.XX) Universal Device Name Error (23.XX) -106 Code Description Corrective Actions 19,01 IN COMMAND Rejected by _ Controller. Software use only 19,02 IN COMMAND Timeout. _ 1. Cycle power. 2. Replace controller board. 3. Replace hard drive. Code Description Corrective Actions 20,01 Unlatch command rejected. 20,02 Timeout period expired waiting for head to stop. 1. Check door latch solenoid wiring. 2. Check ability of door to latch Code Description Corrective Actions 22,01 FC SERVICE event not received. _ 22,02 Insufficient material to complete job.
Not used on HP Designjet 3D printers Code Description Corrective Actions 23,01 UDN controller command failed. 23,02 UDN controller command timed out. 1. Check network for connectivity. 2. Cycle power.