4.0 Non-Code Errors A. “Build Error” displayed on LCD B. Tip Depth Incorrect C. “Corrupted Upgrade” displayed on LCD D. “Carrier Invalid or Empty” displayed on LCD E. Door Latch F. “Door Open” displayed on LCD G. Download H. Loss of Extrusion (LOE) I. Lights J. Material/Unload Error (failed to load/unload material) K. Network Communications L. Pauses during build M. Power Up/Boot N. “Can’t Find Home - Check Modeling Base” displayed on LCD O. Power Down P. System VERY slow to reach temperature Q. Calibration issues R. Z Calibration failure S. Noise -107 A. "Build Error" displayed on LCD 1. Part stops building before complete. 1. Partial or bad model file sent to unit.
- Check and reprocess the STL and redownload B. Tip depth is incorrect 1. Tip Depth is wrong (too deep or above the modeling base) 1. Run Z tip calibration. 2. Check and/or clean the Z foam sensor. 3. Replace the Z foam assembly and sensor C. "Corrupted Upgrade" Displayed on LCD 1. Verify the printer firmware CD is the correct gender. (Same as the system) 2. Cycle power and try download again. If not possible or fails again replace hard drive. 3. Verify the hard drive and the controller board are gendered correctly.