-117 L. Pauses During Build 1. Chamber won't heat up to at least - 77 degrees 1. Verify top and side panels and insulation are installed. 2. Verify chamber fans are operating. 3. Check J3 heater connector/pins on the PDB. 4. Heater bad. Check heater resistance - should be 36 +/- 5 ohms. 5. Relay failed on PDB, replace PDB. 6. See error code 14-40. 2. Head not maintaining temperature. 1. Low AC input power. Make sure system is NOT attached to an ext. cord/power strip 2. Umbilical cable connector loose at head board - check to make sure it is fully seated. 3. One of the four heaters is bad. Check resistance of heaters should read about 92 Ohms 4. T/C board is bad. Replace T/C board 5.
Head Board is bad. Replace Head Board 6. If head board with LED’s is present, check model and support 120VDC LEDs at head board. • If both model (upper) and support (lower) LEDs are illuminated, head heater is bad. Replace head. • If only the model LED (lower) is illuminated, replace the 120VDC power supply • If only the support LED (upper) is illuminated, replace the power distribution board 7. If head board with LED’s is not present, use volt meter to check for 120 VDC at head board. • If 120VDC present at both model and sup- port side, heater is bad. Replace head. • If no 120VDC at support side, replace 120VDC power supply. • If no 120VDC at model side, replace power distribution board.
8. Check ground between Toggle Plate and Head Board. If open, check for missing washers on head. 9. The heater wires in the umbilical cable are broken.Replace cable. 10. Head T/C is crushed. Check by ohming from the T/C connector pin to the head body. Reading should show open. If not, replace toggle head. 11. Replace toggle head 12. See error codes 14-39, 14-100 and 14-133.