HP — Removing the XY table

Figure 253: Left side Y belt retaining clip mounting screw locations Remove the outer mounting screws Loosen, but do not remove the inner mounting screws 20. Using a 5 ⁄ 16 ” box wrench, remove the outer Y belt retaining clip mount- ing screws from the right side. See Figure 254. 21. Using a 5 ⁄ 16 ” box wrench, loosen, but do not remove, the inner Y belt retaining clip mounting screws from the right side. See Figure 254. 22. Pull the right side Y belt out from the retaining clip. Figure 254: Right side Y belt retaining clip mounting screw locations Remove the outer mounting screws Loosen, but do not remove the inner mounting screws 23. Move the translator to the rear of the printer. 24.

Using a 5 ⁄ 16 ” nut driver, remove the right side X guide rod mounting screws. See Figure 255. -287