Figure 277: Gauge reading at correct X belt tension (Shading indicates acceptable range) 77. If the tension is out of the range specified above, adjust the belt tension by turning the X belt tensioning nut on the X-Drive Idler/Tension Adjust gear. See Figure 278. Figure 278: X-Drive Belt Tension Adjustment X belt tension bolt 78. Remove the belt fixture and run the head back and forth several times. 79. Continue to adjust and check the tension until the tension meets specifi- cation. 80. Repeat steps 68 - 71 to zero the dial indicator. 81. Reinstall a wire tie around the umbilical hose. See Figure 279. -302