HP — Z tip to base (ZT2B)

Offset Calibrations Adjusting Z Calibration and XY Tip Offset Z calibration is needed to adjust the slight differences in tip heights. XY Tip Offset is required to correct for the slight differences in tip alignment. Failure to perform these calibrations will result in poor part quality and possible LOE’s. Z and Tip Offset calibrations are mandatory whenever the tips are replaced. If Tip Replacement is chosen from the Interface Panel Maintenance>Machine>Tip>Replace , you will be prompted to perform the calibrations as a part of the replacement procedure. These calibrations can also be run without performing a Tip Replacement.

From Idle , choose Maintenance>Machine>Tip then Calibrate Z or Calibrate XY. Z Calibration 1. Press Maintenance. 2. Press Machine. 3. Press Tip. 4. Press Calibrate Z. 5. Press Start Part . The printer will automatically build a Z Calibration part (one square of model and one of support). The system will then measure and calibrate the Z Axis for tip depth and tip level. (Build time is approx- imately 5 minutes). 6. Repeat steps 1-5 to verify proper calibration. NOTE: Unusual circumstances may require that the Z calibration values be entered manually. To change these values, see “Entering Z Calibration values manually (Firmware version 9.1 or newer)” on page 338.

Entering Z Calibration values manually (Firmware version 9.1 or newer) Z tip to base (ZT2B) ZT2B is the Z distance from the support tip to the Z substrate sensor activation point. If unable to calibrate automatically, this value may need to be set to default in order to proceed with automatic calibration. The default value is -0.0700”. 1. While the printer is at Idle , enter standby mode by pressing the Standby... button. 2. Enter the Service Calibration menu by pressing the following button sequence on the display panel: 3,2,3,3,1 . See Figure 319. -338 CAUTION: Do not use the Z calibration or XY tip offset from the test parts menu to calibrate the system.