Figure 319: Service Calibration button sequence Button 0 Button 1 Button 2 Button 3 3. Press the Edit Configuration button. 4. Press the Next... button. 6. Press the ZT2B (Z tip to base) button. 5. Press the Next... button. 7. Enter the calibration value by pressing the Increment , Decrement and Next Digit buttons. NOTE: The value for ZT2B must be between -0.1500” and 0.0000”. 8. When finished, press Done... 9. Press the Save and reboot button. 10. The printer will reboot and return to idle. 11. Perform automatic Z calibration. See “Z Calibration” on page 338. Z tip to tip (ZT2T) ZT2T is the Z distance from the model tip to the support tip.
A positive ZT2T means the support tip is higher than the model tip. If a support layer on top of model is too thick, add 0.010” to the ZT2T. If a model layer does not stick to supports, subtract 0.010” from the ZT2T. If unable to calibrate automatically, this value may need to be set to default in order to proceed with automatic calibration. The default value is 0.0000”. 1. While the printer is at Idle , enter standby mode by pressing the Standby... button. 2. Enter the Service Calibration menu by pressing the following button sequence on the display panel: 3,2,3,3,1 . See Figure 319. 3. Press the Edit Configuration button. -339