4. Press the Next... button. 6. Press the ZT2T (Z tip to tip) button. 5. Press the Next... button. 7. Enter the calibration value by pressing the Increment , Decrement and Next Digit buttons. NOTE: The value for ZT2T must be between -0.0500” and 0.0500”. 8. When finished, press Done... 10. Press the Done... button. 9. Press the Next... button until you reach the last page. 11. Press the Save and reboot button. 12. The printer will reboot and return to idle. 13. Perform automatic Z calibration. See “Z Calibration” on page 338. XY Tip Calibration 1. Press Maintenance. 2. Press Machine. 3. Press Tip. 4. Press Calibrate XY. 5. Press Start Part.
The printer will automatically build an XY Tip Calibra- tion part. (Build time is approximately 10 minutes). 6. When the XY Tip Calibration part is complete the printer will display Remove Part and Select XY Adjustment - X:0, Y:0 7. Remove the XY Tip Calibration part from the printer. 8. Inspect the part and calibrate the X and Y axes as follows (See Figure 320 ). A. Use the magnifier from the Startup Kit to view the support road. B. Identify the location on the +X or –X side of the part where the support road is best centered within the model boundaries. C. Read the number closest to this location. This is the required X Tip Offset adjustment, in mils.
If the number is on the -X side, a negative offset is required. D. Select Increment or Decrement to input the X offset adjustment - the value will change in the upper display window (by default, the printer will be ready to accept the X value). E. Once you have entered the X offset value, Select Y and repeat the procedure for Y Offset value. 9. Select Done after you have input the X and Y tip offsets. The printer will return to Maintenance . 10. Repeat steps 1-9 to verify proper calibration. -340