HP — Entering XY Tip Calibration values manually (Firmware version 9.1 or newer)

Figure 320: Example XY Tip Calibration Part. This example requires an adjustment of X = + 2 mils, Y = - 4 mils NOTE: Unusual circumstances may require that the XY Tip Calibration values be entered manually. To change these values, see “Entering XY Tip Calibration values manually (Firmware version 9.1 or newer)” on page 341. Entering XY Tip Calibration values manually (Firmware version 9.1 or newer) XY Tip is the XY distance from model tip to the support tip. To move support roads to the right (+X), apply a positive offset. To move support roads to the back (+Y), apply a positive offset.

If the calibration model is too far off to read, these values may be set to default as a starting point for calibration. The default values are X: 0.780” and Y: 0.000”. 1. While the printer is at Idle , enter standby mode by pressing the Standby... button. 2. Enter the Service Calibration menu by pressing the following button sequence on the display panel: 3,2,3,3,1 . See Figure 321. -341