HP — Entering XY Tip Calibration values manually (Firmware version 9.1 or newer)

Figure 321: Service Calibration button sequence Button 0 Button 1 Button 2 Button 3 4. Press the Next... button. 3. Press the Edit Configuration button. 5. Press the Next... button. 6. Press the XTIP (X tip offset) button. 7. Enter the calibration value by pressing the Increment , Decrement and Next Digit buttons. NOTE: The value for XTIP must be between 0.7300” and 0.8300”, For example, the value from Figure 320 is + 2, you would increment the current value by +0.002”. 8. When finished, press Done... 9. Press the YTIP (Y tip offset) button. 10. Enter the calibration value by pressing the Increment , Decrement and Next Digit buttons. NOTE:

The value for YTIP must be between -0.0500” and 0.0500”, For example, the value from Figure 320 is - 4, you would decrement the current value by -0.004”. 11. When finished, press Done... 12. Press the Next... button until you reach the last page. 13. Press the Done... button. 14. Press the Save and reboot button. 15. The printer will reboot and return to idle. 16. Perform automatic XY Tip Calibration, see “XY Tip Calibration” on page 340. -342