HP — Performing part based calibration for HP Designjet 3D from the Service Calibration menu (Firmware version 9.1 or newer)

Part Based Calibration Required Tools • Set of basic service tools • 6” digital calipers • HP Designjet 3D Diagnostic Software CD (Printer firmware versions older than 9.1) Part based calibration consists of building a part and then taking six measurements - front, right, left, rear, left rear and left front. These measurements are then entered using HP Designjet 3D Diagnostic Software. When to Perform Part Based calibration Part Based calibration needs to be performed after replacing the XY table assembly. Part Based calibration is performed to eliminate any skewing in the X and Y axes.

Performing part based calibration for HP Designjet 3D from the Service Calibration menu (Firmware version 9.1 or newer) 1. While the printer is at Idle , enter standby mode by pressing the Standby... button. 2. Enter the Service Calibration menu by pressing the following button sequence on the display panel: 3,2,3,3,1 . See Figure 322. Figure 322: Service Calibration button sequence Button 0 Button 1 Button 2 Button 3 4. The printer will ask “Do you want to zero settings and reboot?” Press Yes . 3. Press the Reset Part Based Calibration button. 5. Reboot the printer. -343